1kV及下耐火电缆
1kV and below Fire Resistive Cable |
|
|
标准
GB12706、GB12666、IEC331。另可根据顾客指定标准或技术协议设计制造。
Standard
GB 12706,GB12666,IEC331.And it could be produced according to
the appointed standard or technical agreement required by the
customers.
使用特性
额定电压U0 /U:0.6/1kV及以下
敷设温度≥0℃,弯曲半径≥8D(D为电缆外径)
Application Properties
Rated Voltage of U0 /U: 0.6/1kV and below
Laying and installation temperature
≥0℃,Permissible bending radius of cable ≥8D(D-the diameter of cable) |

|
|
|
| 型号及名称、用途
Type & Description |
|
型号 Type
|
名称
Description
|
用途
Application
|
|
铜芯
Cu
|
铝芯
Al
|
|
NH-VV
|
NH-VLV
|
聚氯乙烯绝缘氯乙烯护套耐火电力电缆
PVC insulated PVC sheathed fire
resistive power cable
|
主要用于火灾现场应急照明,消防泵及消防电梯、消防风机的电力
传输。
Used
for power transmission of emergency lighting,fire pump,fire elevator and
fire blower in case of fire accident
|
|
NH-YJV
|
NH-YJLV
|
交联聚乙烯绝缘聚氯乙烯护套耐火电力电缆
XLPE insulated PVC sheathed fire
resistive power cable
|
|
NG-VV22
|
NH-VLV22
|
聚氯乙烯绝缘聚氯乙烯护套钢带铠装耐火电力电缆
PVC insulated PVC sheathed steel
tape armoured fire resistive power cable
|
|
NH-YJV22
|
NH-YJLV22
|
交联聚乙烯绝缘聚氯乙烯护套钢带铠装耐火电力电缆
XlPE insulated PVC sheathed steel
tape armoured fire resistive power cable
|
|
|
| 规格范围
Size |
|
型号
Type
|
芯数
Number of Cores
|
标称截面
Nominal
Cross Sectional (mm2)
|
|
铜芯Cu
|
铝芯Al
|
|
NH-VV
|
NH-VLV
|
1
|
16-500
|
|
NH-YJV
|
NH-YJLV
|
|
NH-VV22
|
NH-VLV22
|
2~5
|
16-300
|
|
NH-YJV22
|
NH-YJLV22
|
|
|
|
技术要求
产品耐火试验应达到GB 12666.6或IEC 331 之相应规定。
Technical Data
The fire resistive test is conformity with the relevant specification of GB 12666.6 or IEC 331. |
|
|
|
|
|
|